Background: Several methods have been developed for detection of sequence variation in genes and each has its advantages and disadvantages. A disadvantage of them is that the simpler, cost-effective methods are commonly perceived as being less sensitive in their detection of sequence variation, whereas those with proven sensitivity have a requirement for complex or expensive laboratory equipment. In this context, we undertook improvements to the conformation sensitive gel electrophoresis (CSGE) method which provides a cost-effective approach to mutation detection and compared the results with scanning carried out using denaturing high performance liquid chromatography (DHPLC) which utilises a dedicated analyser. Methods: We designed PCR primers to amplify the seven protein-coding exons of the human SPP2 gene which encodes secreted phosphoprotein 24 (spp24) such that the amplified products included the immediately-adjacent intronic regions. Five improvements were made to the CSGE method that was used to the scan the PCR-amplified DNA. The scanning was then repeated using DHPLC and the results were compared. Results: Using CSGE, a single nucleotide polymorphism was discovered in exon 2 and another in intron 2 of the gene. Re-scanning of the same regions by DHPLC detected no additional sequence polymorphisms. Conclusion: With modification of the original protocol, CSGE is capable of providing a simple and cost-effective approach to the detection of DNA sequence polymorphisms that appears to be comparable in sensitivity to DHPLC.
Khorram Khorshid,H R and Dalgleish,R . (2008). The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography. Iranian Biomedical Journal, 12(2), 109-114. doi: -
MLA
Khorram Khorshid,H R , and Dalgleish,R . "The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography", Iranian Biomedical Journal, 12, 2, 2008, 109-114. doi: -
HARVARD
Khorram Khorshid H R, Dalgleish R. (2008). 'The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography', Iranian Biomedical Journal, 12(2), pp. 109-114. doi: -
CHICAGO
H R Khorram Khorshid and R Dalgleish, "The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography," Iranian Biomedical Journal, 12 2 (2008): 109-114, doi: -
VANCOUVER
Khorram Khorshid H R, Dalgleish R. The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography. Iranian Biomedical Journal. 2008;12(2):109-114. doi: -